Binance futures market data over microwave (RF) — Tokyo to London, by the 24 h pass
Captured at the venue in Tokyo and delivered at our London endpoint. Top-of-book price changes of 13 instruments arrive over a microwave (RF) link, everything else over our fiber line. One WebSocket and one API key carry both paths. Each top-of-book update says which path delivered it. Sold as 24 h passes that start at your payment. No subscription. Nothing renews.
Two paths from Tokyo to London
Top-of-book price changes of these 13 instruments travel over the microwave (RF) link. Everything else arrives over our fiber line on the same connection. The endpoint merges both paths: you see every update once, delivered by the path that brought it first, and never an older update after a newer one.
~66.0msone-way, Tokyo → London over RF
~69.3msour fiber line on the same route
Where you connect
The data is captured at the venue; you connect at the endpoint, with the login and the messages of every realtime endpoint.
| Market | Endpoint | Port | JSON endpoint | SBE endpoint | Buy |
|---|---|---|---|---|---|
| Binance USDT-M | London | 14010 | ws://lon-rf.cryptostruct.com:14010/api/v6 | ws://lon-rf.cryptostruct.com:14010/api/v6/sbe | Whole market →Instruments → |
Same API key and protocol as your other realtime endpoints. Each top-of-book update says whether it arrived over RF.
Over RF — 13 instruments
Top-of-book price changes of these 13 instruments travel over the microwave (RF) link.
Two ways to receive it
One connection carries it all. What does not travel over RF — the order book, trades, mark and index price, funding, liquidations and every other instrument of the market — arrives over our fiber line. Each top-of-book update says which path delivered it. The fiber part belongs to the pass: there is no fiber access to buy on top.
You receive only the top-of-book updates that arrived over RF — considerably fewer messages. For clients that already receive this market from Tokyo over their own line. It is not a gap-free top of book: a quantity-only change never travels over the link, and a price change whose fiber copy reached the endpoint first is not repeated.
If the RF link is interrupted, every update arrives over fiber and your pass keeps running. With RF only, no top-of-book updates arrive until the link is back.
How a pass works
A pass starts when your payment is confirmed and runs 24 hours for each pass you buy, plus 2 hours to get set up.
Buying again while a pass is running adds the new time to its end — nothing overlaps. No subscription. Nothing renews.
Single instruments are the 13 whose top of book travels over RF. The whole market includes the same 13 over RF and adds every other instrument over our fiber line.
Your API key and the endpoint are shown right after checkout. It is the same key as on every realtime endpoint.
Price
€299 / instrument · 24 h · €399 / market · 24 h
| Passes | Whole market | Instrument | Buy |
|---|---|---|---|
| 1 | €399 | €299 | 1 × 24 h → |
| 14+ | €360 | €270 | 14 × 24 h → |
| 30+ | €320 | €240 | 30 × 24 h → |
| 180+ | €280 | €210 | 180 × 24 h → |
| 365+ | €240 | €180 | 365 × 24 h → |
Prices per 24 h, by the number of passes in one order. More passes cost less per 24 h — the price follows the quantity of one order. Paid by card or in USDC at checkout. No subscription. Nothing renews.
How to buy a pass
- Open the RF tab of the shop and pick the whole market or single instruments from the list of 13.
- Choose the number of passes: €399 per market and €299 per instrument per 24 h pass; from 14 passes €360 / €270, from 30 €320 / €240, from 180 €280 / €210, from 365 €240 / €180 (market / instrument).
- Pay by card or in USDC. A pass starts when your payment is confirmed and runs 24 hours for each pass you buy, plus 2 hours to get set up.
- Your API key and the endpoint are shown right after checkout.
- Connect with the connection guide, or hand the machine-readable spec to a coding agent.
More on this endpoint
Questions about this endpoint
What travels over the microwave (RF) link, and what arrives over fiber?
Top-of-book price changes of these 13 instruments travel over the microwave (RF) link: BTCUSDT, ETHUSDT, SOLUSDT, XRPUSDT, BNBUSDT, DOGEUSDT, ADAUSDT, NEARUSDT, HYPEUSDT, XMRUSDT, ZECUSDT, 1000PEPEUSDT, BTCUSDC. One connection carries it all. What does not travel over RF — the order book, trades, mark and index price, funding, liquidations and every other instrument of the market — arrives over our fiber line. Each top-of-book update says which path delivered it. The fiber part belongs to the pass: there is no fiber access to buy on top.
What are the one-way line figures over RF and over fiber?
~66.0 ms one-way, Tokyo → London over RF; ~69.3 ms our fiber line on the same route. Both figures: line latency from the site where the venue is captured to our endpoint — the venue's own latency and the on-ramp to your client come on top.
Do I need fiber access in addition to an RF pass?
No. The fiber part belongs to the pass: there is no fiber access to buy on top. Single instruments are the 13 whose top of book travels over RF. The whole market includes the same 13 over RF and adds every other instrument over our fiber line.
What is RF only, and is it a complete top of book?
RF only is one option in your subscribe request (topOfBookRfUdpOnly). You receive only the top-of-book updates that arrived over RF — considerably fewer messages. For clients that already receive this market from Tokyo over their own line. It is not a gap-free top of book: a quantity-only change never travels over the link, and a price change whose fiber copy reached the endpoint first is not repeated.
What happens if the RF link is interrupted?
If the RF link is interrupted, every update arrives over fiber and your pass keeps running. With RF only, no top-of-book updates arrive until the link is back.
When does an RF pass start, and what happens when it ends?
A pass starts when your payment is confirmed and runs 24 hours for each pass you buy, plus 2 hours to get set up. Buying again while a pass is running adds the new time to its end — nothing overlaps. When a pass ends, the endpoint closes the connection at its next periodic check. No subscription. Nothing renews.
What does an RF pass cost?
€399 per market and €299 per instrument per 24 h pass that starts at your payment; more passes in one order cost less per 24 h (market / instrument: from 14 passes €360 / €270, from 30 €320 / €240, from 180 €280 / €210, from 365 €240 / €180). Paid by card or in USDC at checkout. No subscription. Nothing renews.
How do I connect to the RF endpoint, and can a coding agent write the client?
The same login, messages and API key as on every realtime endpoint, plus the path element on each top-of-book message — the connection guide covers it, and the machine-readable spec is the same guide for a coding agent. Your account page shows a prompt written for this endpoint that never contains your key. An RF pass is bought on the website, not through the MCP server or the HTTP checkout.